• Factory Exterior - Chicken House Solutions

Blog

7 Steps To Ensure Stable Feeding With Pralson Feeders
Time : Sep 08, 2026
  • Pralson feeders support stable feed distribution through organized equipment layouts, precise adjustment, and practical poultry-house integration for commercial production.
  • Automatic chicken feeders reduce repetitive feeding work while coordinated equipment helps maintain predictable feed movement across different house sections.

  • Commercial chicken feeders require suitable conveying, suspension, control, maintenance, and electrical configurations to support continuous farm operation.

  • Proper equipment selection connects feed storage, conveying capacity, feeder positioning, and flock development into one measurable poultry feedingsystem.

  • Pralson feeders combine practical engineering specifications with scalable poultry equipment planning, creating a structured foundation for efficient feeding, maintenance, automation, and long-term commercial farm development.

Get professional poultry farm construction guidance, equipment selection solutions, and the latest price lists, whatsApp to +8618830120193, click to learn more:

Taiyu (HK) Group Equipment

Taiyu (HK) Group Equipment



Select The Correct Feeder Configuration



Data is for reference only.Swipe horizontally to view full table.

Engineering ItemPralson Feeder Reference
Pan Outer Diameter380 mm
Feed Holding Capacity6.5 kg
Bird Access Positions18
Drive Pipe Diameter44 mm
Pan Material Thickness2.0 mm
Cleaning Time Per Unit45 s
Recommended Installation Length150 m

Pralson feeders should be selected according to the physical requirements of the poultry house rather than purchased as isolated components.

A 360° suspension arrangement can accommodate different equipment orientations, while a 450 mm height-adjustment range provides additional flexibility for 

automatic chicken feeders during positioning.

Pralson feeders create defined feeding points while supporting practical integration of commercial chicken feeders into larger poultry-house layouts.



Establish Accurate Feed Conveying



Data is for reference only.Swipe horizontally to view full table.

Conveying ParameterEngineering Data
Auger Diameter45 mm
Feed-Line Diameter50 mm
Conveyor Rotation Speed52 rpm
Feed Delivery Capacity1,200 kg/h
Trial Feed Quantity35 kg
Conveyor Running Time4.8 min
Average Pan Fill Depth18 mm

Pralson feeders combine conveying lines with feeder pans so feed can move from supply points toward distribution points without manual carrying.

During commissioning, operators can evaluate a 2.9 A motor-current reading together with a 0.7 kg feed-return quantity when checking poultry feeding system behavior.

Pralson feeders help establish a measurable conveying process for commercial chicken feeders operating across extended house layouts.



Adjust The Feeder According To Bird Growth



Data is for reference only.Swipe horizontally to view full table.

Bird AgeReference Body WeightFeeder HeightFeed Access Space/Bird
1–7 Days180–220 g5–7 cm2.5 cm
8–14 Days450–520 g8–10 cm3.2 cm
15–21 Days850–980 g11–13 cm4.0 cm
22–28 Days1,450–1,650 g14–16 cm4.8 cm
29–35 Days2,200–2,500 g17–19 cm5.5 cm

Pralson feeders can be adjusted as flock development progresses, keeping feeding equipment aligned with changing bird behavior.

A routine inspection before the first feeding cycle provides operators with an opportunity to correct positioning before intensive operation of commercial chicken feeders.

Pralson feeders consequently support a more structured poultry feeding system where equipment adjustment follows production development.



Coordinate Feed Supply With Line Operation



Data is for reference only.Swipe horizontally to view full table.

Production LayoutMotor PowerFeed DeliveryMaximum Refill Time
45 M Line0.75 kW600 kg/h4 min
60 M Line1.10 kW900 kg/h5 min
75 M Line1.50 kW1,200 kg/h6 min
90 M Line2.20 kW1,600 kg/h7 min

Pralson feeders perform more effectively when drive configuration is matched with the physical scale of the poultry house.

Commercial silo configurations can range from 3 to 50 tonnes, allowing automatic chicken feeders to be planned alongside feed-storage requirements.

Pralson feeders can therefore connect internal feeding equipment with broader poultry feeding system infrastructure.



Maintain Mechanical Accuracy



Data is for reference only.Swipe horizontally to view full table.

Maintenance ComponentTechnical ReferenceInspection Focus
Drive Motor0.75–2.20 kWMotor operation
Feed Pipe45–60 mmConveying passage
Feed Pan1.8–3.5 kgFeed distribution
Feed Hopper80–150 kgFeed reserve
Feed Chain12–18 m/minMovement condition
Feed Sensor24 VSignal response
Suspension System0.5–2.5 mLine positioning

Pralson feeders should be included in scheduled inspection routines because dust, feed particles, humidity, vibration, and repeated operating cycles can affect 

mechanical components.

Intensive facilities may operate feeding equipment for more than 18 hours per day while daily feed transportation can exceed 4 tonnes.

Pralson feeders therefore provide an equipment platform that should be managed through planned maintenance within commercial chicken feeders projects.



What Makes Pralson A Better Equipment Investment?



Data is for reference only.Swipe horizontally to view full table.

Equipment FeaturePralson Technical ConfigurationProduction Application
Pan StructureGrill-less open panDirect bird access
Feed-Line PipeGalvanized steel constructionContinuous conveying
Cross Auger75 / 90 / 100 mm optionsSilo-to-house transfer
Control PanSensor or micro-switch operationFeed-level management
SiloGalvanized steel or fiberglassFeed storage
SuspensionWinch, pulleys and stainless-steel cablesHeight adjustment
Feed RoutingT-drop with spherical jointMulti-line distribution

Pralson feeders are designed as components within a complete poultry-house equipment architecture rather than isolated feeding products.

Cross-auger diameters of 75 mm, 90 mm, and 100 mm provide configuration choices for connecting storage equipment with automatic chicken feeders.

Pralson feeders consequently support broader poultry feeding system engineering where conveying, storage, and distribution must operate together.



Compare The Equipment By Production Function



Data is for reference only.Swipe horizontally to view full table.

Evaluation CategoryRound FeederRectangular Feeder
Feed Delivery Speed25 kg/min30 kg/min
Motor Power Requirement0.75 kW1.10 kW
Recommended Bird Capacity55 birds/unit70 birds/section
Equipment Weight4.8 kg7.2 kg
Installation Angle360°180°
Design Service Life8 years10 years

Pralson feeders can be evaluated according to house configuration, operating requirements, and equipment integration instead of one universal feeder structure.

A 25 kg/min conveying rate represents a different configuration from a 30 kg/min rate when selecting commercial chicken feeders for different production layouts.

Pralson feeders give project designers practical options for developing a poultry feeding system around specific farm requirements.



Build The Feeding System Around The Complete House



Data is for reference only.Swipe horizontally to view full table.

Project ElementEngineering Specification
Feed-Line Length120 m
Pipe Diameter45 mm
Pan Spacing75 cm
Suspension Height180 cm
Drive-Shaft Speed350 rpm
Hopper Capacity100 kg
Operating Voltage380 V

Pralson feeders should be planned from the house drawing, flock quantity, feeding route, power supply, and equipment-access requirements.

A 380 V operating supply and 350 rpm drive-shaft speed demonstrate why automatic chicken feeders require coordinated electrical and mechanical planning.

Pralson feeders can form part of a complete poultry feeding system when project dimensions and equipment interfaces are established before installation.



Turn Stable Feeding Into A Commercial Equipment Advantage



Data is for reference only.Swipe horizontally to view full table.

Investment ObjectiveTechnical TargetEquipment Contribution
Feed DistributionVariation below 150 g between pansConsistent feed movement
Inspection Management8 inspection cyclesStructured equipment checks
Maintenance Planning14-day cleaning cycleScheduled sanitation
Controller Response2.5 sFaster equipment feedback
Program Management50 stored feeding recordsAutomated feeding planning
Motor ProtectionIP55Electrical equipment protection
CommunicationRS485Control-system integration

Stable feeding depends on coordinated mechanical conveying, feeder access, automatic control, and maintenance rather than one isolated equipment feature.

Pralson feeders provide a foundation for commercial chicken feeders projects that require organized feed distribution and equipment-based management.

A professionally configured pralson feeder system can support modern poultry feeding system planning across feeding, storage, control, and maintenance stages.



Frequently Asked Questions



Q1: What factors should be considered when selecting pralson feeders?

Pralson feeders should be selected according to flock size, house dimensions, feeding-line arrangement, conveying requirements, and control architecture, with project configurations potentially covering 20–200 m feeding-line layouts.

Q2: How can pralson feeders support automated poultry feeding?

Pralson feeders can integrate feeder pans, conveying equipment, feed-level sensing, and control components, with a 24 V control circuit providing a practical reference for equipment automation.

Q3: Why should feeder maintenance be included in project planning?

Pralson feeders operate as mechanical systems exposed to dust, feed particles, vibration, and repeated cycles, so scheduled inspection can help maintain equipment performance and reduce avoidable operational interruptions.



Taiyu (HK) Group - One Of China Largest Pralson Feeders Manufacturer



  • Pralson feeders provide engineered feed distribution equipment integrating feeder pans, conveying components, control units, suspension assemblies, and storage interfaces for commercial poultry projects.

  • Global factory-direct supply supports equipment sourcing through standardized specifications, project coordination, production scheduling, and international shipment management.

  • Poultry equipment solutions can be configured around house dimensions, flock capacity, electrical requirements, feeding routes, and installation conditions for different commercial farm projects.

  • Turn-key engineering coordinates feeding equipment with ventilation, environmental control, drinking, manure handling, and other poultry-house systems through project-level equipment planning.

  • International project support combines factory manufacturing, technical documentation, equipment configuration, and delivery coordination for complete poultry production facilities.



Contact Us To Received Your Customized Poultry Farm Plan



Headquarters And Branchs

poultry farm

Hong Kong Headquarter Management Team


  • Hong Kong Headquarter Taiyu Industrial Group CO., LTD

  • China Hebei Best Machinery And Equipment CO., LTD

  • Nigeria Vanke Machinery And Equipment CO., LTD

  • Tanzania Best Machinery And Equipment CO., LTD

  • Ethiopia Best Hebei Machinery Manufacturing PLC


supplier and manufacture chicken cage and poultry farm equipment (2)

China Branch


supplier and manufacture chicken cage and poultry farm equipment (3)

Nigeria Branch


supplier and manufacture chicken cage and poultry farm equipment (4)

Tanzania Branch


chicken cage design (1)

Ethiopia Branch


Reception /24 WhatsApp NO. : +8618830120193

Email:sales@bestchickencage.com

FAQ

Q:

What Are The Water Filtration Requirements For Plasson Poultry Equipment?

A:
Particle filtration accuracy is maintained at 80–120 microns for pipeline protection.
Suspended solid concentration is controlled below 40 mg per liter for system stability.
Backwash flow rate reaches 1.5–2.0 m³ per hour for effective filter regeneration.
Q:

What Are The Pipeline Dimension Standards In Plasson Poultry Equipment?

A:
Main water lines are typically designed with 22–32 mm internal diameter for stable flow distribution.
Branch lines operate with 16–20 mm diameter for balanced pressure across drinking points.
Maximum pipeline length per zone reaches 80–120 meters without pressure loss impact.
Q:

What Are The Bird Age Adaptation Settings In Plasson Poultry Equipment

A:
Drinking line height adjustment range spans 10–45 cm across full growth cycle stages.
Water flow sensitivity is adjusted to 60–100 ml per minute for different age groups.
Bird access spacing is optimized at 8–15 birds per nipple depending on growth phase.

Message